{"id":1965,"date":"2024-07-15T17:51:26","date_gmt":"2024-07-15T17:51:26","guid":{"rendered":"https:\/\/arabtechnollc.com\/?page_id=1965"},"modified":"2024-07-15T17:54:17","modified_gmt":"2024-07-15T17:54:17","slug":"turbine-oil-varnish-control-for-ge-frame-9e-power-turbine","status":"publish","type":"page","link":"https:\/\/arabtechnollc.com\/index.php\/turbine-oil-varnish-control-for-ge-frame-9e-power-turbine\/","title":{"rendered":"Turbine Oil Varnish Control for GE Frame 9E Power Turbine"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"1965\" class=\"elementor elementor-1965\">\n\t\t\t\t<div class=\"elementor-element elementor-element-12bc519 e-flex e-con-boxed e-con e-parent\" data-id=\"12bc519\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e718f0c elementor-widget elementor-widget-heading\" data-id=\"e718f0c\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<style>\/*! elementor - v3.21.0 - 22-05-2024 *\/\n.elementor-heading-title{padding:0;margin:0;line-height:1}.elementor-widget-heading .elementor-heading-title[class*=elementor-size-]>a{color:inherit;font-size:inherit;line-height:inherit}.elementor-widget-heading .elementor-heading-title.elementor-size-small{font-size:15px}.elementor-widget-heading .elementor-heading-title.elementor-size-medium{font-size:19px}.elementor-widget-heading .elementor-heading-title.elementor-size-large{font-size:29px}.elementor-widget-heading .elementor-heading-title.elementor-size-xl{font-size:39px}.elementor-widget-heading .elementor-heading-title.elementor-size-xxl{font-size:59px}<\/style><h2 class=\"elementor-heading-title elementor-size-default\">Turbine Oil Varnish Control for GE Frame 9E Power Turbine<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4f61235 e-flex e-con-boxed e-con e-parent\" data-id=\"4f61235\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7edc205 elementor-widget elementor-widget-text-editor\" data-id=\"7edc205\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<style>\/*! elementor - v3.21.0 - 22-05-2024 *\/\n.elementor-widget-text-editor.elementor-drop-cap-view-stacked .elementor-drop-cap{background-color:#69727d;color:#fff}.elementor-widget-text-editor.elementor-drop-cap-view-framed .elementor-drop-cap{color:#69727d;border:3px solid;background-color:transparent}.elementor-widget-text-editor:not(.elementor-drop-cap-view-default) .elementor-drop-cap{margin-top:8px}.elementor-widget-text-editor:not(.elementor-drop-cap-view-default) .elementor-drop-cap-letter{width:1em;height:1em}.elementor-widget-text-editor .elementor-drop-cap{float:left;text-align:center;line-height:1;font-size:50px}.elementor-widget-text-editor .elementor-drop-cap-letter{display:inline-block}<\/style>\t\t\t\t<div class=\"gray\"><strong>System:<\/strong>\u00a0GE Frame 9E Power Turbine<\/div><div class=\"gray\"><strong>Oil Brand:<\/strong>\u00a0Shell Turbo CC32<\/div><div class=\"gray\"><strong>Oil Volume:<\/strong>\u00a013,000 liters<\/div><div>\u00a0<\/div><div class=\"gray\"><strong>Problem:<\/strong><\/div><div class=\"text\">Sludge and Varnish deposition in Turbine Oil and Hydraulic Control Oil system, caused Turbine trips, Servo valves failures, Sticking valves, high bearing temperatures, filter choking, restart problems and poor oil cooler efficiency.<\/div><div>\u00a0<\/div><div class=\"gray\"><strong>Summary of project:<\/strong><\/div><div class=\"text\">HYPRO SVR1200 Soluble Varnish and contamination removal unit was selected for turbine Oil and System cleaning in order to eliminate the associated problems. To quantify the results, bi-monthly Oil analysis was conducted to monitor the improvement in oil condition. Within 3 months of installation of HYPRO SVR1200 unit, the results were achieved. Eliminated turbine trip events related to sticky valves, Improvement in bearing temperatures, reduction of filter consumption due to reduced filter choking, oil cooler efficiency improved.<\/div><div>\u00a0<\/div><div class=\"gray\"><strong>Quantified goals:<\/strong><\/div><div class=\"text\">ISO 4406 Particle count &lt; 17\/14\/10<br \/>MPC &lt; 15<br \/>TAN &lt; 0.06<\/div>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-67633c4 elementor-widget elementor-widget-image\" data-id=\"67633c4\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<style>\/*! elementor - v3.21.0 - 22-05-2024 *\/\n.elementor-widget-image{text-align:center}.elementor-widget-image a{display:inline-block}.elementor-widget-image a img[src$=\".svg\"]{width:48px}.elementor-widget-image img{vertical-align:middle;display:inline-block}<\/style>\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"541\" height=\"131\" src=\"https:\/\/arabtechnollc.com\/wp-content\/uploads\/2024\/07\/20.png\" class=\"attachment-large size-large wp-image-1969\" alt=\"\" srcset=\"https:\/\/arabtechnollc.com\/wp-content\/uploads\/2024\/07\/20.png 541w, https:\/\/arabtechnollc.com\/wp-content\/uploads\/2024\/07\/20-300x73.png 300w\" sizes=\"(max-width: 541px) 100vw, 541px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-29722da elementor-widget elementor-widget-image\" data-id=\"29722da\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/arabtechnollc.com\/wp-content\/uploads\/2024\/07\/19-1024x576-1.png\" class=\"attachment-large size-large wp-image-1968\" alt=\"\" srcset=\"https:\/\/arabtechnollc.com\/wp-content\/uploads\/2024\/07\/19-1024x576-1.png 1024w, https:\/\/arabtechnollc.com\/wp-content\/uploads\/2024\/07\/19-1024x576-1-300x169.png 300w, https:\/\/arabtechnollc.com\/wp-content\/uploads\/2024\/07\/19-1024x576-1-768x432.png 768w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Turbine Oil Varnish Control for GE Frame 9E Power Turbine System:\u00a0GE Frame 9E Power TurbineOil Brand:\u00a0Shell Turbo CC32Oil Volume:\u00a013,000 liters\u00a0Problem:Sludge and Varnish deposition in Turbine Oil and Hydraulic Control Oil system, caused Turbine trips, Servo valves failures, Sticking valves, high bearing temperatures, filter choking, restart problems and poor oil cooler efficiency.\u00a0Summary of project:HYPRO SVR1200 Soluble [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1965","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/arabtechnollc.com\/index.php\/wp-json\/wp\/v2\/pages\/1965","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/arabtechnollc.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/arabtechnollc.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/arabtechnollc.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/arabtechnollc.com\/index.php\/wp-json\/wp\/v2\/comments?post=1965"}],"version-history":[{"count":4,"href":"https:\/\/arabtechnollc.com\/index.php\/wp-json\/wp\/v2\/pages\/1965\/revisions"}],"predecessor-version":[{"id":1972,"href":"https:\/\/arabtechnollc.com\/index.php\/wp-json\/wp\/v2\/pages\/1965\/revisions\/1972"}],"wp:attachment":[{"href":"https:\/\/arabtechnollc.com\/index.php\/wp-json\/wp\/v2\/media?parent=1965"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}